Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
RGO (Porto Alegre) ; 68: e20200005, 2020. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1091885

ABSTRACT

ABSTRACT Objective to analyze the surface roughness and color stability of the composite resin after surface treatment with the aluminum oxide discs and subsequent exposure to the Advanced Teeth Whitening Strips. Methods 20 specimens of the Filtek Z350XT restorer (3M®) were prepared and daily subjected to home bleaching for 30 minutes during 14 days. A precision rugosimeter was used in order to verify the roughness by means of 3 random readings in the same direction in each sample. For color stability the CIELAB system (L*, a*, b* values) was used through the spectrophotometer (MINOLTA CR -321, Japan). The means of the test specimens as well as the mean of each group were calculated using the random readings. Data statistical analysis were performed by ANOVA- analysis of variance. The level of significance was set at 5% (p ≤ 0.05). Results Roughness did not present great numerical variations. No statistically significant difference between the means obtained concerning the surface roughness of the composite resin with p = 0.44 was observed. However, it was found that there was a statistically significant difference between the means obtained in relation to the color stability of the composite resin, p=0. 007. Conclusion It was concluded that pre-contoured strips containing 6% hydrogen peroxide do not have a significant adverse effect on the roughness of Z350XT (3M®) resin. However, it was also concluded that according to the color stability analysis performed, there may be an indication of the restoration replacement after the bleaching treatment, due to their color change.


RESUMO Objetivo Analisar a rugosidade superficial e a estabilidade da cor da resina composta após tratamento de superfície com os discos de óxido de alumínio e posterior exposição à fita clareadora Advanced Teeth Whitening Strips. Métodos Foram confeccionados 20 corpos de prova do restaurador universal Filtek Z350XT (3M®), estes, foram submetidos ao clareamento caseiro por 30 minutos diários durante 14 dias. Utilizou-se um rugosímetro de precisão para verificação da rugosidade através de 3 leituras aleatórias no mesmo sentido em cada amostra, e para estabilidade de cor foi utilizado o sistema CIELAB (valores L*, a*, b*), através do espectofotômetro (MINOLTA CR-321, Japão). As leituras coletadas possibilitaram o cálculo das médias dos corpos de prova e a média de cada grupo. Em seguida, os dados foram submetidos a tratamento estatístico pela análise de variância ANOVA. O nível de significância estabelecido foi de 5% (p≤0,05). Resultados a rugosidade não sofreu grandes variações numéricas e também não houve diferença estatisticamente significantes entre as médias obtidas em relação a rugosidade superficial da resina composta (p=0,44). Contudo, verificou-se que houve diferenças estatisticamente significantes entre as medias obtidas em relação à estabilidade de cor da resina composta, com p= 0,007. Conclusão As fitas pré-contornadas contendo peróxido de hidrogênio a 6% não provocam efeito adverso significantes sobre a rugosidade da resina Z350XT (3M®). Contudo, também concluímos que, de acordo com a análise de estabilidade de cor realizada, poderá haver indicação da substituição das restaurações após o tratamento clareador devido à alteração na coloração das mesmas.

2.
Braz. dent. sci ; 17(3): 50-53, 2014. ilus, tab
Article in English | LILACS, BBO | ID: lil-743036

ABSTRACT

The objective of this study was to evaluate the influence of different speeds using the piston device in the shear bond strength. 48 cylinders of composed resin had been confectioned (Solidex),and were divided randomly in four groups (n=12). The specimens were adapted to the device for the shear bond strenth test and were taken to an universal testing machine with a load cell of 1000 Kg. The test were carried through with four different speeds: group A: 0.5; group B: 1.0; group C: 1.5 and group D: 2.0 mm/min. The mean and standard deviations, in Kgf, were: A - 66,31 (10,24); B - 64,53 (20,40); C - 75,23 (11,84) and D - 66,62 (13,81). The data were submitted to ANOVA (p = 0.13). The results indicated that it did not have statistical significant difference between the groups A, B, C and D concluding that the speed in this type of test, with this device, can be varied without modify results


O objetivo do presente estudo foi avaliar a influência de diferentes velocidades usando o dispositivo pistão para o ensaio de cisalhamento. Foram confeccionados 48 cilindros em resina composta microhíbrida (Solidex), divididos aleatoriamente em quatro grupos (n = 12). As amostras foram adaptadas ao dispositivo para o ensaio de cisalhamento e levadas a uma máquina de ensaios universal com uma célula de carga de 1000 Kg. Os ensaios foram realizados com quatro velocidades diferentes: grupo A: 0,5 mm/min; grupo B 1,0 mm/ min; grupo C: 1,5 mm/min e grupo D 2,0 mm/min. Os valores médios e desvios padrão obtidos, em Kgf, foram: grupo A: 66,31 ± 10,24; grupo B: 64,53 ± 20,40; grupo C: 75,23 ± 11,84 e grupo D: 66,62 ± 13,81. Os dados foram submetidos ao teste ANOVA (p = 0,13). Os resultados indicaram que não houve diferença estatisticamente significante entre os grupos A, B, C e D concluindo que se pode variar a velocidade neste tipo de ensaio, utilizando o dispositivo pistão, sem que os resultados fossem alterados


Subject(s)
Composite Resins , Materials Testing , Shear Strength
3.
ImplantNews ; 9(6a): 88-93, 2012. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-850998

ABSTRACT

O objetivo neste trabalho foi avaliar, por meio da extensometria, a distribuição de tensões ao redor de implantes em função dos diferentes locais para carregamento e configuração (linear e compensada). Para tanto, em um bloco de poliuretano, foram posicionados paralelos entre si e com uma configuração linear, implantes autorrosqueáveis de hexágono externo, com dimensões de 3,75 mm x 13 mm, a uma distância de 7 mm, de centro a centro. Em outro bloco, a fixação do meio foi deslocada em 2 mm para gerar uma configuração compensada (offset). Pilares protéticos Micro-unit, com 3 mm de cinta, foram instalados sobre as fixações. Com duas matrizes em aço inoxidável foram confeccionados dez enceramentos para cada bloco (n = 10). A seguir, esses padrões foram fundidos com uma liga de Co-Cr. Quatro extensômetros (strain gauges) foram colados na superfície superior de cada bloco, tangenciando a plataforma de cada fixação. Um carregamento de 30 kg durante dez segundos foi feito em cinco posições (A, B, C, D, E), sendo repetido três vezes para aquisição dos dados (em µɛ) pelo aparelho condicionador de sinais. Os dados obtidos foram submetidos a análise de variância (RM Anova) e teste de Tukey (p < 0,05). Como conclusão da análise dos resultados obtidos, pudemos observar que não houve diferença entre as configurações linear e compensada; havendo diferença estatisticamente significante para os locais de carregamento.


The aim of this study was to evaluate through strain gauge methods the load distribution around dental implants regarding different sites and configurations (linear and offset). Three cylindrical implants with external hexagon (3.75 mm x 13mm) connection were fixed parallel in a polyurethane model with 7 mm between their centers in a linear configuration. In another block, the middle implant was positioned 2 mm offset. After, micro-unit abutments (3 mm of metallic collar height) were tightened. Ten wax patterns were created for each block (n = 10) and cast in Cobalt-Chromium alloy. Four strain gauges were positioned on the upper surface of each polyurethane model around the implants. A 30 kg axial load was applied for 10 seconds in five positions (A, B, C, D, and E), with three repeated measurements for data aquisition (in µɛ) by the multichannel bridge machine. Data were submitted to Anova and Tukey´s test (p < 0.05). It was concluded that: 1) no difference was seen between the linear and offset configurations and 2) there was statistical significance for different loading sites


Subject(s)
Dental Implants , Dental Prosthesis
4.
HU rev ; 37(4): 413-419, dez. 2011.
Article in Portuguese | LILACS | ID: lil-661229

ABSTRACT

A prótese total convencional provê substitutos para uma porção perdida do organismo, ou seja, os dentes. A substituição deve ser acompanhada de técnicas e critérios que visam à satisfação do paciente submetido a tal tratamento. Cada paciente é único e deve expressar seus sentimentos e anseios com relação ao tratamento para que no fim, a satisfação seja garantida. Os fatores que levam a satisfação de um paciente que recebe tratamento podem ser distribuídos em psicossociais, físicos, desconforto/dor. O objetivo deste estudo é a análise desses fatores que podem influenciar na satisfação do paciente submetido ao tratamento


Conventional complete denture provides substitutes for a lost portion of the organism, or in other words, teeth. The substitution should be followed by techniques and criteria, which focuses the satisfatcion of the patient submited to this treatment. Each patient is unique and should manifest his fellings and wishes about treatment, and what he hopes of it, that at the end of treatment, his satisfaction be guaranteed. The factors that brings satisfaction to a patient who receives this treatment may be distributed in psicossocial, factors, discomfort/pain. The goal of this study is to analyze these factors that hás influence in satisfaction of the patients who receive treatment of conventional total prosthesis


Subject(s)
Patient Satisfaction , Denture, Complete , Pain , Oral Health , Dental Health Services , Emotions , Mastication
5.
RFO UPF ; 16(2)maio-ago. 2011.
Article in Portuguese | LILACS | ID: lil-611998

ABSTRACT

Objetivo e relato de caso: O objetivo deste trabalho é relatar a técnica de zona neutra utilizada na reabilitação protética de um paciente com sequela cirúrgica na região de comissura labial direita em virtude da ressecção de câncer bucal, destacando-se a dificuldade decorrente da limitada abertura bucal do paciente e a utilização de um condicionador de tecidos para determinação da zona neutra na região de sequela cirúrgica. A prótese total foi obtida com a técnica, proporcionando boa retenção e estabilidade, que possibilitaram ao paciente a reabilitação funcional de seu sistema mastigatório. Considerações finais: A técnica da zona neutra para confecção de próteses totais determina o espaço intrabucal para posicionamento dos dentes e base da prótese em que existe uma neutralização das forças proporcionadas pelos lábios, bochechas e língua. Constitui-se, assim, numa alternativa para pacientes que apresentam histórico de dificuldades de adaptação da prótese total convencional inferior por fatores diversos, tais como reabsorção acentuada do rebordo alveolar, sequelas cirúrgicas e outros. A reabilitação por meio dessa técnica possibilita maior satisfação aos pacientes em razão de uma melhor retenção e estabilidade da prótese inferior.

6.
Braz. j. oral sci ; 9(1): 11-15, Jan.-Mar. 2010. ilus, tab, graf
Article in English | LILACS, BBO | ID: lil-578039

ABSTRACT

Aim: To evaluate the occurrence of microstrain around morse taper implants in straight configuration under axial load in a cast monoblock framework. Methods: Three implants were inserted in a polyurethane block and microunit abutments were installed on the implants with 20 Ncm torque. Plastic and machined copings were adapted on the preset waxing to fabricate the framework (n=5). Four strain gauges were attached on the upper surface of the block and then each framework was tightened on the abutments and a vertical load of 30 kg was applied to five points of the framework. Results: The data obtained in the strain gauge analysis were subjected to twoway ANOVA and Tukey’s test (=0.05). There was statistically significant difference (p=0.0222) for the factor application point and the mean microstrain values were: application point B 402,04µ, point A 401.21µ, point E 390.44µ, point D 341.76µand point C 309.19 µ. Conclusions: There was no microstrain difference between plastic and machined copings during axial loading. Difference in the application point was observed, but remained within bone physiological limits.


Subject(s)
Dental Implants , Dental Prosthesis, Implant-Supported , Dental Stress Analysis , Denture, Partial, Fixed , Analysis of Variance , Dental Abutments , Materials Testing , Stress, Mechanical
7.
Rev. bras. ciênc. saúde ; 14(1): 93-98, 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-790566

ABSTRACT

Avaliar a influência de diferentes dispositivos decarregamento na resistência de união ao cisalhamento entreo titânio comercialmente puro (Ticp) e uma resina indireta.Materiais e Método: Foram confeccionados trinta cilindrosmetálicos (CM) em Ticp (altura: 5 mm; diâmetro: 4 mm). OsCM tiveram sua superfície adesiva jateada com Al2O3 110 μm.Todos os cilindros foram imersos em álcool isopropílico 10% elimpos em banho ultra-sônico (10 min). Duas camadas(espessura: 0,2 mm) de Sinfony Opaco foram aplicadas sobrea superfície jateada dos CM e submetidas à polimerização nasunidades Visio Alfa e Visio Beta. Com auxílio de um dispositivode teflon, a resina de recobrimento estético Sinfony foi aplicada(altura: 5 mm; diâmetro: 4 mm) sobre a camada de opaco epolimerizada de acordo com as recomendações do fabricante.As amostras foram divididas em três grupos, de acordo com otipo de dispositivo para carregamento utilizado para o ensaiode cisalhamento (n=10): Gr1- pistão, Gr2- cinzel reto e Gr3-cinzel reto com entalhe. As amostras foram submetidas aoensaio de cisalhamento na máquina de ensaio universal. Osdados (MPa) foram submetidos à análise de variância (ANOVA).Resultados: As médias e desvios-padrões obtidos foram: Gr1-5,49±1,41 MPa; Gr2- 5,37±0,8 MPa e Gr3- 5,56±1,92 MPa.Conclusão: Todos os dispositivos testados apresentaramdesempenho semelhante na análise da união metal/resina(p=0,9550>0,05)...


The aim of this study was to evaluate the influenceof the different devices on the shear bond strength betweenthe titanium (Ticp) and an indirect resin. Material and Method:Thirty metallic cylinders of Ticp (height: 5 mm; diameter: 4mm) obtained by machining of pure commercially titaniumbar (Ticp). The metallic cylinders had their adhesive surfacesandblasted (Al2O3; 110μm). All cylinders were immerged inisopropyl alcohol 10% and were cleaned ultrasonically (10min). Two layers of the resin Opaque Sinfony were applied onthe metallic cylinders and cured in the Visio Alfa and VisioBeta units, according to the manufacturer’s recommendation.The esthetic resin Sinfony was applied (height: 5 mm; diameter:4 mm) on the opaque layer using a teflon device, according tothe manufacturer’s instructions. The specimens were dividedinto three groups, according to the shear device used (n=10):Gr1: piston, Gr2: knife without a groove; Gr3: knife with a groove.The shear test was performed in a universal testing machine.Bond strength results were analyzed using one-way ANOVA.Results: The means and standard deviations obtained were:Gr1- 5.49 ± 1.41 MPa, Gr2- 5.37 ± 0.8 MPa and Gr3- 5.56 ±1.92 MPa. Conclusion: All devices used showed similarperformance on the bond strength between metal/resin(p=0.9550>0.05)...


Subject(s)
Humans , Dental Materials , Shear Strength , Titanium
SELECTION OF CITATIONS
SEARCH DETAIL